2.3.2 CRT
Disassembly procedure
1. Discharge through a resistor of about 25 MD in-
serted between the anode cap terminal and GND
(ground frame).
Anode Cap
Screw
Notes on disassembly
•. High voltage is applied to the CRT. Keep this in
mind and take care.
D.Y.
Screw
2
Fig. 2-19
2. Disconnect the cable connectors (2) coming from
the DY (deflection yoke) shown in Fig. 2-19 from
the board.
3. Disconnect the grounding wire connector coming
from the middle of the wire which makes connec-
tion between the CRT fixing screws 2 and
3,
from
the board.
4. Remove the socket shown in Fig. 2.19.
5. Remove four screws 1 - 4 shown in fig. 2-19.
CTC: M4xl16 x4
OW:
M4 x2
PW: M4 x 0.8 x 1 6 x 2
• Carry out above procedure in reverse for reassem-
bly.
• Screws
3
and 4 should be used as shown below.
CRT
Grounding
Case
F'W
Terminal
Fig. 2-20