2
Hardware Installation
2.6.11 Chassis Open Alarm Connector
The system board supports the chassis intrusion detection function.
To use this function, connect the chassis intrusion sensor cable from
the chassis to J1. Whenever a chassis component has been removed,
the sensor sends signal to J1 alerting you of a chassis intrusion
event. To disable this function, place a jumper cap over J1.
Hardware Doctor Utility
Install "Hardware Doctor". By default, the chassis open alarm
function is disabled. When enabled, a warning message will appear
when the chassis is open. The utility can also be configured so
that a beeping alarm will sound when the chassis is open. Refer
to the "Hardware Doctor" section in chapter 4 for more infor-
mation.
46
Chassis
signal
Ground
1
2

Advertisement