Programming and Checkout of Wireless Zones

Each wireless zone must be programmed in order to become operational. To program the
zones, refer to the procedures for zone programming in Section 22: #93 Menu Mode
Programming. After all wireless zones are installed, each partition of the security system
should be checked. To check each partition containing wireless zones, refer to "Checkout
Procedure for Wireless Zones" in Section 29: Testing the System.
8-10
Product
Wireless Keypad
Wireless
Bi-directional Keypad
Glassbreak Detector
PIR Detector
Program As
Input Type
Description
House ID
• Can be used to turn the burglary
protection on and off.
• Features the same built-in panic
functions as wired keypads.
• The keypad is identified as zone
"00" on wired keypads when it
transmits with a low battery.
House ID
(Used with 5800TM Module)
• Operates the system similarly to
wired keypads.
• Can indicate system status via its
3 LEDs and sounder.
• Includes 3 panic keys.
• House ID must be set.
• Requires 5800TM Transmitter
Module (must be enabled in #93
Menu Mode –Device
Programming and assigned to a
partition in 1*48).
RF
• Requires both sound and shock of
breaking glass to cause an alarm
to be transmitted.
• Has a unique input code.
RF
• Dual-element passive infrared
detector/transmitter with built-in
selectable pulse count.
• Has a unique input code.
Note: There is a 3-minute lockout
between fault transmissions to con-
serve battery life.