Alarm Monitoring - Cisco ASR 1001-HX Hardware Installation Manual

Table of Contents

Advertisement

Alarm Monitoring

To prevent overheating of the chassis, ensure that your system is drawing cool inlet air. Over temperature
Caution
conditions may occur if the system is drawing in the exhaust air of other equipment. Ensure adequate
clearance around the sides of the chassis so that cooling air can flow through the chassis interior unimpeded
and exhaust air exits the chassis and is not drawn into the inlet vent of another device.
Alarm Monitoring
The Cisco ASR 1001-HX Router and Cisco ASR 1002-HX Router display the CRIT, MAJ, and MIN alarm
indicator LEDs. The three system alarm LEDs on the Cisco ASR 1002-HX Router provide visual alarm
notification in the router. These LEDs indicate router status at all times, but you must directly observe these
LEDs to become aware of a router alarm condition. Additionally, you can use the show facility-alarm status
command to view the alarms.
Router# show facility-alarm status
System Totals
Source
------
Power Supply Module 0
Power Supply Bay 1
[0]
GigabitEthernet0/0/0
State Down [2]
GigabitEthernet0/0/1
State Down [2]
xcvr container 0/0/2
GigabitEthernet0/0/3
State Down [2]
GigabitEthernet0/0/4
State Down [2]
GigabitEthernet0/0/5
State Down [2]
GigabitEthernet0/0/6
State Down [2]
GigabitEthernet0/0/7
State Down [2]
TenGigabitEthernet0/1/0
State Down [36]
xcvr container 0/1/1
TenGigabitEthernet0/1/2
State Down [36]
xcvr container 0/1/3
.
.
.
Note
There is no external alarm monitoring facility on the Cisco ASR 1002-HX Router.
To clear a visual alarm, you must resolve the alarm condition. The clear facility-alarm command does not
clear an alarm LED on the Cisco ASR 1001-HX Router or Cisco ASR 1002-HX Router. For example, if a
critical alarm LED is illuminated because an active EPA was removed without a graceful deactivation of the
EPA, the only way to resolve that alarm is to replace the EPA.
Cisco ASR 1001-HX Router and Cisco ASR 1002-HX Router Hardware Installation Guide
86
Critical: 2
Major: 0
Minor: 0
Time
------
Jan 21 2016 18:06:16
Jan 21 2016 18:06:15
Jan 21 2016 18:08:21
Jan 21 2016 18:08:21
Jan 21 2016 18:08:21
Jan 21 2016 18:08:21
Jan 21 2016 18:08:21
Jan 21 2016 18:08:21
Jan 21 2016 18:08:21
Jan 21 2016 18:08:21
Jan 21 2016 18:08:21
Jan 21 2016 18:08:21
Jan 21 2016 18:08:21
Jan 21 2016 18:08:21
Power Up and Initial Configuration
Severity
Description [Index]
--------
-------------------
CRITICAL
Power Supply Failure [0]
CRITICAL
Power Supply/FAN Module Missing
INFO
Physical Port Administrative
INFO
Physical Port Administrative
INFO
Transceiver Missing [0]
INFO
Physical Port Administrative
INFO
Physical Port Administrative
INFO
Physical Port Administrative
INFO
Physical Port Administrative
INFO
Physical Port Administrative
INFO
Physical Port Administrative
INFO
Transceiver Missing [0]
INFO
Physical Port Administrative
INFO
Transceiver Missing [0]