Associating The Track Module With A Detection Module; Associating Track With Nqa; Associating Track With Bfd - HP 5130 EI Series Configuration Manual

High availability
Hide thumbs Also See for 5130 EI Series:
Table of Contents

Advertisement

Tasks at a glance
(Required.)
Associating Track with static routing
Associating Track with PBR
Associating Track with Smart Link
Associating the Track module with a detection
module

Associating Track with NQA

NQA supports multiple operation types to analyze network performance, services, and service quality.
For example, an NQA operation can periodically detect whether a destination is reachable, or whether
the TCP connection to a TCP server can be set up.
An NQA operation operates as follows when it is associated with a track entry:
If the consecutive failures reach the specified threshold, the NQA module notifies the Track module
that the tracked object has malfunctioned. Then the Track module sets the track entry to Negative
state.
If the specified threshold is not reached, the NQA module notifies the Track module that the tracked
object is operating correctly. The Track module then sets the track entry to Positive state.
For more information about NQA, see Network Management and Monitoring Configuration Guide.
To associate Track with NQA:
Step
1.
Enter system view.
2.
Create a track entry,
associate it with an NQA
reaction entry, and specify the
delay time for the Track
module to notify the
associated application
module when the track entry
status changes.

Associating Track with BFD

BFD supports the control packet mode and echo packet mode. A track entry can only be associated with
the echo-mode BFD session. For more information about BFD, see
BFD operates as follows when it is associated with a track entry:
Associating the Track module with an application
Command
system-view
track track-entry-number nqa entry
admin-name operation-tag reaction
item-number [ delay { negative
negative-time | positive
positive-time } * ]
131
module:
Remarks
N/A
By default, no track entry is
created.
If the specified NQA operation or
the reaction entry in the track entry
does not exist, the status of the
track entry is NotReady.
"Configuring
BFD."