Step
3.
Configure the authentication
mode for multihop BFD
control packets.
4.
Set the destination port
number for multihop BFD
control packets.
5.
Set the multihop detection
time multiplier.
6.
Set the minimum interval for
receiving multihop BFD
control packets.
7.
Set the minimum interval for
transmitting multihop BFD
control packets.

Configuring a BFD template

This feature is available in Release 3108P01 and later versions.
Perform this task to specify BFD parameters in a template for sessions without next hops. You can
configure BFD parameters for LSPs and PWs through a BFD template.
To configure a BFD template:
Step
1.
Enter system view.
2.
Create a BFD template and
enter BFD template view.
3.
Configure the authentication
mode for BFD control packets.
4.
Set the detection time
multiplier.
5.
Set the minimum interval for
receiving BFD control packets.
6.
Set the minimum interval for
transmitting BFD control
packets.
Command
For Release 3106:
bfd multi-hop
authentication-mode simple
key-id { cipher cipher-string |
plain plain-string }
For Release 3108P01 and later
versions:
bfd multi-hop
authentication-mode { m-md5
| m-sha1 | md5 | sha1 |
simple } key-id { cipher
cipher-string | plain
plain-string }
bfd multi-hop destination-port
port-number
bfd multi-hop detect-multiplier
value
bfd multi-hop min-receive-interval
value
bfd multi-hop
min-transmit-interval value
Command
system-view
bfd template template-name
bfd authentication-mode { m-md5
| m-sha1 | md5 | sha1 | simple }
key-id { cipher cipher-string | plain
plain-string }
bfd detect-multiplier value
bfd min-receive-interval value
bfd min-transmit-interval value
127
Remarks
By default, no authentication is
performed.
The default setting is 4784.
The default setting is 5.
The default setting is 400
milliseconds.
The default setting is 400
milliseconds.
Remarks
N/A
By default, no BFD template is
created.
By default, no authentication is
performed.
The default setting is 5.
The default setting is 400
milliseconds.
The default setting is 400
milliseconds.