SpectraPure
Membrane Output Calculation
Membranes produce the rated gallons per day (GPD) at 60 psi (4.1 bars)
operating pressure, 77°F (25°C) operating temperature and 500 ppm total
dissolved solids.
Membrane output gallons per day (GPD) depends on operating pressure,
water temperature and the ppm TDS in the feed water.
Expected GPD = Rated GPD × PCF × TCF
PCF is the pressure correction factor
TCF is the temperature correction factor
Calculation of Pressure Correction Factor (PCF): The output (GPD) from
the membrane is directly proportional to the applied pressure.
The membrane is rated to produce the rated GPD at 60 psi. For any
pressure other than 60 psi the output GPD is multipled by the PCF.
PCF = Line Pressure (in psi) ÷ 60
Calculation of Temperature Correction Factor (TCF): The output (GPD)
also decreases with decrease in temperature. This is because water viscosity
increases with decrease in water temperature.
Temperature Correction Factor Table (TCF)
°F /°C
41.0 /5
42.8 /6
44.6 /7
46.4 /8
48.2 /9
50.0 /10
51.8 /11
53.6 /12
55.4 /13
57.2/14
SpectraPure
16
TCF
°F /°C
0.521
59.0 /15
0.540
60.8 /16
0.560
62.6 /17
0.578
64.4 /18
0.598
66.2 /19
0.620
68.0 /20
0.640
69.8 /21
0.661
71.6 /22
0.684
73.4 /23
0.707
75.2 /24
Inc.
®
480.894.5437 Call us toll-free 1.800.685.2783
2167 East Fifth St, Tempe, Arizona 85281
®
TCF
°F /°C
0.730
77.0 /25
0.754
78.8 /26
0.779
80.6 /27
0.804
82.4 /28
0.830
84.2 /29
0.857
86.0 /30
0.884
87.8 /31
0.912
89.6 /32
0.941
91.4 /33
0.970
93.2 /34
TCF
1.000
1.031
1.063
1.094
1.127
1.161
1.196
1.232
1.267
1.304