Tariff [s] (Function No.: 398)
Pseudo tariff metering setting (tariff is based on call duration). The Tariff parameter
sets the call cost according to call duration. Set how often in seconds do you want to
transmit pulses. Smaller number means more expansive call. Zero means not to
transmit pulses according to call duration.
Setting options: 0-255 s
Setting step: 1 s
Default setting: 0 s
Time limit [min] (Function No.: 399)
After time elapsing is call connection terminated immediately. You can hear beep 30s
before end of call. 10s before end you can hear beep every second. The "0" setting
means that the function is disabled.
Setting options: 0-255 min
Setting step: 1 min
Default setting: 0 (disabled)
Bank No (Function No.:-)
Special function – with FW 1.5x and 3.5x only. Don't use this parameter and the menu
'Free minutes bank', with detailed setting of free minutes banks, for standard Easy
Gate.
GSM routing parameters
Incoming calls from GSM contain the CLI. According to received CLI Easy Gate can do
following:
Reject the call;
Use function CallBack – automatic call to the GSM subscriber;
Automatic dial in. EasyGate dials preprogrammed PBX subscriber number (for
example switchboard operator) to be connected with calling GSM subscriber.
FXS line Off-Hook to DISA timeout [ms] (Function No.: 500)
Timeout between FXS line Off-Hook and automatic dial in according to parameter
"Dial in" in the table.
Setting options: 100-25500 ms
Setting step: 100 ms
Default setting: 2000 ms