2N EasyGate Pro User Manual page 26

Hide thumbs Also See for EasyGate Pro:
Table of Contents

Advertisement

3.2 Table of Parameters
All programmable parameters are listed in this section. Each parameter is
accompanied with the unit used, function number (if available) for programming via a
telephone line, description of EasyGate's behavior, setting options, setting step and
default (initialization) value.
Numeric parameters must be set in unit listed in the parameter description. For
parameters with different setting are values defined in the parameters description (for
phone line programming in parenthesis). When phone line programming is used,
character
can't be included in the string, because it is dedicated for confirmation
of the new parameter value.
Telephone interface FXS parameters
Dialing parameters
Type of dialing (Function No.:100)
Select the dialing type to be received by EasyGate on the FXS interface. 2N® EasyGate
accepts only the selected type of dialing, ignoring the others.
Setting options:
DTMF (0) -EasyGate receives tone dialing only.
Pulse (1)-EasyGate receives pulse dialing only
Default setting:DTMF
Time to dial [s] (Function No.:101)
Timeout during which EasyGate waits for further digits to be dialed. It starts to
establish connection when this timeout passes.
Setting options: 1-255 s
Setting step: 1 s
Default setting: 5 s
Minimal On Hook [ms] (Function No.:102)
The minimum line current break that EasyGate evaluates as hang-up.
Setting options: 100-25500 ms
Setting step: 100 ms
Default setting: 500 ms