6.3.6 Manually accumulated total

The values (weight and count) shown on the display can be added to
the values in the accumulator by pressing the [M+] key. The
"WEIGHT" display will show the total weight, the "COUNT" display
will show the total accumulated count and the "UNIT WEIGHT"
display shows the number of times items have been added to the
accumulation memory. The values will be displayed for 2 seconds
before returning to normal.
The scale must return to zero or a negative number before another
sample can be added to the memory.
More products can then be added and the [M+] key pressed again.
This can continue for up to 99 entries or until the capacity of the
"WEIGHT" display is exceeded.
To observe the total value stored, press the [M+] key when the scale
is at zero. The total will be displayed for 2 seconds.
To clear the memory, first press [M+] to recall the total from the
memory and then press [CE] to clear all values from the memory.

6.3.7 Automatic accumulated total

The scale can be set to automatically accumulate total when a
weight is placed on the scale. This eliminates the need to press the
[M+] key to store values into the memory. However the [M+] key is
still active and can be pressed to store the values immediately. In
this case, the values will not be stored when the scale returns to
zero.
See the PARAMETERS Section for details on how to enable
Automatic Accumulation.