3.3

Comparison with e-STUDIO230/280

Process
1. Photoconductive drum
Sensitivity
Surface potential
2. Charging
Grid voltage
3. Data writing
Light source
Light amount
4. Development
Magnetic roller
Auto-toner
Toner supply
Toner-empty detection
Toner
Developer material
Developer bias
5. Transfer
Transfer bias
6. Separation
7. Discharge
Discharging position
Discharge LED
8. Cleaning
Method
Recovered toner
9. Fusing
Method
Cleaning
Heater
December 2005 © TOSHIBA TEC
e-STUDIO230/280
OD-1600 (OPC ø30)
Highly sensitized/durable drum
-475 V
Scorotron method
-495 V
Semiconductor laser
(Adjustment not required)
2
4.0 nJ/mm
One magnetic roller
Magnetic bridge-circuit method
Toner cartridge
Density detection method
T-2320, T-2320E, T-2320D, T-2320C,
T-2320T
D-2320, D-2320C
DC-357 V Adjustable output
(during printing)
AC 1100 V (Adjustment not required,
during printing)
DC+150 V Fixed (others)
Adjustable output (Constant current)
+600 V (Adjustment not required)
Adjustable output
(Constant current)
Exposure after cleaning
Red LED
Cleaning blade
Reuse (There is the recovered toner
supply mechanism.)
Long-life fuser roller method
Fuser roller:
Thin roller coated with fluoroplastic
(ø30)
Pressure roller:
PFA tube roller (ø30)
Cleaning roller for pressure roller (ø16)
Heater lamp
Turned ON/OFF by thermistor