4) Temperature control at Energy Saving Mode
This equipment has the following two types of temperature control for saving energy and returns to
ready status to perform printing in each mode upon printing request.
The period of time from the printing request to this mode can be set in "xxx" or by xxx.
Setting procedure:
T.B.D
Auto Power Save Mode (T.B.D):
When the printing is not performed in a specified period of time (default setting: 15 min.) after the
previous printing is completed, the equipment enters to Auto Power Save Mode to turn OFF the
heater lamp.
Auto Shut Off Mode (T.B.D):
When the printing is not performed in a specified period of time (default setting: 10 min.) after the
equipment entered to Auto Power Save Mode, the equipment then enters to Auto Shut Off Mode to
turn OFF the heater lamp.
Warming-up
°C
170
Temperature
of fuser roller
Heater lamp
ON
0
December 2005 © TOSHIBA TEC
Ready
During printing
Fig. 13-4
13 - 7
Auto Power Save Mode
Fixed time ( 08-XXX )
( Heater lamp OFF )
Fixed time ( 08-XXX )
e-STUDIO163/203 FUSER / EXIT UNIT
Auto
Shut Off
Mode
OFF