(3)
Pull out the center heater lamp and side
heater lamp.
Notes:
•
When installing the heater lamps, be sure
not to mix up the upper heater lamp and
the lower heater lamp.
The upper heater lamp has a coil wound
up on its center part, and the lower heater
lamp has coils wound up on its both
edges.
•
When installing the heater lamps, be sure
to face up their weld sides.
•
Do not touch the lamps directly with your
hands.
•
Connect the harness of the terminal M3 to
the center heater lamp, and connect the
harness of the terminal M4 to the side
heater lamp.
[G] Fuser roller
(1)
Take off the center heater lamp and the side
heater lamp.
P.13-15 "[F] Center heater lamp / Side
heater lamp (LAMP1/LAMP2)"
(2)
Take off the separation fingers.
P.13-15 "[E] Separation finger"
(3)
Take out the fuser roller upward.
Notes:
•
When installing the fuser roller, slide each
bearing on both edges of the roller out-
ward so that the bearings will engage with
the frame and the installation will be
secured.
•
Do not apply force onto the roller because
it may be deformed.
e-STUDIO163/203 FUSER / EXIT UNIT
Upper side : center heater lamp
Lower side : side heater lamp
13 - 16
Center heater lamp
Side heater lamp
Fig. 13-20
Weld
Fig. 13-21
Fuser roller
Fig. 13-22
December 2005 © TOSHIBA TEC