Code 39; Code 39 Enable/Disable; Code 39 Check Character Calculation - Datalogic PD9330 Product Reference Manual

Industrial corded handheld area imager bar code reader
Hide thumbs Also See for PD9330:
Table of Contents

Advertisement

The following options apply to the Code 39 symbology.

Code 39 Enable/Disable

$CC3EN01(CR)
Code 39 = Enable

Code 39 Check Character Calculation

Enable this option to enables/disables calculation and verification of an
optional Code 39 check character. When disabled, any check character in
the label is treated as a data character
DEFAULT
$CC3CC01(CR)
Code 39 Check Character Calculation =
Calculate Std Check
Product Reference Guide

CODE 39

$CC3EN00(CR)
.
$CC3CC00(CR)
Code 39 Check Character Calculation = Don't Calculate
$CC3CC02(CR)
Code 39 Check Character Calculation =
Calculate Mod 7 Check (no AR)
Enter/Exit Programming Mode
Code 39 = Disable
DEFAULT