5.8.2. Parameter Update Menu

This menu updates the adjustment parameters. The parameters that can be updated through this menu are
as follows.
Head voltage
Printing position alignment
CW adjustment
Media feed distance
Mechanical parameter
Ink parameter
Ink ID mask
Serial number
Notes :
F1 →
F3 →
F1 →
F3 →
If you update any parameter in the Parameter Update menu, always turn the power
OFF after quitting the menu. The updated parameters will not be stored in the flash
memory unless the system power is turned OFF.
* Update *
HeadRank
CW Adj.
* Update *
Mechparm
Ink ID mask
← F2
PrintPos.
← F4
P. FeedLen.
(1/2)
← F2
Inparm
← F4
serialNo.
(2/2)
178