5.8. PARAMETER MENU
In this menu, you can modify the set values of various adjustment items (adjustment parameter).
The Parameter menu includes the following items.
Initialization item
Initialize.
Update
F1 →
5.8.1. Parameter Initialization Menu
This menu initializes the adjustment parameters. The parameters that can be initialized in this menu are as
follows.
Capping position
Media feed distance
Serial number
Head history
Wiper history
Waste ink history
CR motor history
PF motor history
Pumps
Waste tank
Initialization of all items
F1 →
F3 →
F1 →
F3 →
F1 →
Description
Initializes the adjustment parameters.
Updates the adjustment parameters.
* Parameter *
Initialize
* Initialize *
P. FeedLen
Head
*Initialize*
CR Motor
Pump A
*Initialize*
WasteInk
↓ Select item (P. FeedLen.)
* P. FeedLen. *
Initialize OK ?
↓ ENTER
* P. FeedLen. *
Initialize Parameter
← F2
Update
← F2
serialNo.
← F4
Wiper
(1/3)
← F2
PF Motor
← F4
Pump B
(2/3)
← F2
All
(3/3)
177
Spitfire – Maintenance Manual
Refer to
Parameter Initialization
Menu
Parameter Update Menu
AP-74096, Rev. 1.0, 09/06/05