Load – Loads the selected profile/configuration.
The Falcon will boot with the
profile/configuration that has an asterisk (*) next
to the name.
User Profiles/Configurations can be copied from
one Falcon to another using the Command Line
Interface. Profiles/Configurations can also be
backed up to a USB flash drive and restored if
needed. More information including detailed
step-by-step instructions can be found in
10.6.
Profiles/configurations allow users to create different profiles or
configurations. The profile/configuration can then be saved.
When a profile/configuration is loaded using the Load icon, the
Falcon will load that configuration during its boot process.
For example, if the user wants the Falcon to always boot up
with the default imaging mode to Drive to File with the setting
of E01 with a segment size of 2GB:
1. Turn the Falcon off then back on. This will reset all
settings to its default configuration. This is an important
step to help ensure only the changes desired will be the
changes saved.
2. Go to the Imaging screen and set the Mode to 'Drive to
File.
3. In the Settings, set the image to E01 and set the
segment size to 2GB.
4. In the System Settings, go to User
Profiles/Configurations and tap the New icon.
5. Type a name for this profile. For example, E01-2GB and
tap the OK icon. The profile name should appear on the
screen.