Features; Intended Use; General Safety - Osburn SATURNA Installation And Operating Instructions Manual

Natural gas & propane direct vent gas fireplace insert
Table of Contents

Advertisement

1.2 Features

Ignition system:
Standing pilot ignition system with thermopile and thermocouple flame detection and piezo igniter.
Gas control:
Automatic millivolt powered combination gas control valve with variable flame control for convenience
and on/off switch, optional wall thermostat, and/or optional wireless remote control are available. The
gas valve does not require electricity from an external source.
Fan control
Variable speed control, the knob controls the fan speed in connection with a heat sensitive switch
which turns on when the heater reaches operating temperature. Turning the knob counter-clockwise
turns it to the "Off" position.
Safety controls:
A safety switch (thermocouple) will shut the system down in the event of loss of pilot flame,
installation is not adequate or if flue is blocked.
Outside combustion air supply:
The combustion air supply is obtained entirely from outside the heated living space by the intake of
outside air through the vent termination and down a 3" aluminum vent.

1.3 Intended use

This appliance is intended to be used as a direct vent (top venting) fireplace insert heater and is
suitable for installation into masonry fireplaces, or into certified factory built fireplaces which include a
gas line knockout and proper floor clearances. A masonry fireplace must meet the minimum building
code requirements or the equivalent, for a safe installation.
Factory built fireplaces and their
chimneys must be certified and meet local code requirements. Both must be free from cracks,
blockage, creosote deposits, loose mortar, or other types of deterioration. . In Massachusetts the
Saturna may be installed in a bedroom only when used as a direct vent unit (sealed combustion). For
other states or provinces it may be installed in a bedroom provided that CR89-00 and/or ANSI
A225.1/NFPA 501A standards are followed, all required clearances are met, a wall thermostat is
installed and where the maximum input is within 50 cubic feet of room volume per 1000 BTU/hr,
(i.e.1500 minimum cubic feet) and hooked up to a Simpson GS Dura Vent , Security Chimneys
International (Secure Vent) or Selkirk (Direct-Temp) vent termination.

1.4 General safety

The appliance must be properly connected to a venting system in accordance with local codes. This
unit must not be connected to a chimney or flue serving any other appliance. It is equipped with a
safety control system to protect against improper venting of flue products.
WARNING: Operation of this unit when not connected to a properly installed and
maintained venting system may result in carbon monoxide poisoning.
Installation and repair should be done by a qualified service person. The appliance should be
inspected before use and at least annually by a professional service technician. Provide adequate
5