Osburn SATURNA Installation And Operating Instructions Manual page 28

Natural gas & propane direct vent gas fireplace insert
Table of Contents

Advertisement

3.3.7.5 Altitude adjustment
All valves have been preset and certified for installation at elevations from 0 - 4500 feet (0-1372m)
above sea level. When installing this insert at higher elevations, it is necessary to decrease the input
rating, by changing the existing burner orifice to a smaller size, consult local codes. Input should be
reduced 4% for each additional 1000 feet above sea level. Use Tables 5A & 5B or check with the
local gas authorities for proper orifice size identification. For the USA, derate the heater from sea
level according to the gas installation code.
Altitude adjustment by changing the burner orifice
ALTITUDE
up to (ft)
4500
5500
6500
7500
8500
9500
10500
11500
ALTITUDE
up to (ft)
4500
5500
6500
7500
8500
9500
10500
11500
(Natural Gas)
REDUCTION
ORIFICE SIZE
(%)
-
4
8
12
16
20
24
28
(Propane / LP Gas)
REDUCTION
ORIFICE SIZE
(%)
-
4
8
12
16
20
24
28
TARGET
(DMS)
(BTU/hr)
36
37
38
39
40
40
41
42
TABLE 5A
TARGET
(DMS)
UNPUT
(BTU/hr)
50
35,000
51
33,600
51
32,200
52
30,800
52
29,400
53
28,000
53
26,600
54
25,200
TABLE 5B
MANIFOLD
INPUT
PRESSURE
(in.wc)
35,000
33,600
32,200
30,800
29,400
28,000
26,600
25,200
MANIFOLD
PRESSURE
(in. wc)
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
10
10
10
10
10
10
10
10
28

Advertisement

Table of Contents
loading

Table of Contents