Osburn SATURNA Installation And Operating Instructions Manual page 10

Natural gas & propane direct vent gas fireplace insert
Table of Contents

Advertisement

Minimum Clearances to Combustibles :
Combustible
surface
14.00"
(357mm)
12.50"
(319mm)
A- Combustible side wall to unit
B- Combustible side mantle to unit
C- Combustible top mantle to unit
D- Combustible shelf to unit
E- Minimum floor protection in front of unit
F,G,H- Minimum enclosure dimension
Note:
When using paint or lacquer to finish the mantle, such paint or lacquer must be heat resistant
to prevent discoloration.
Non-combustible
surface
Figure 5
10"
(255mm)
8"
(204mm)
6"
(153mm)
4"
(102mm)
2"
(51mm)
11.25"
(287mm)
9.75"
(249mm)
8.50"
(217mm)
Figure 7a
No floor protection needed,
if unit is sitting at least 5
inches above the floor
Figure 6
COMBUSTIBLE SIDE WALL
COMBUSTIBLE SHELF
COMBUSTIBLE TOP MANTLE
D
A
H
FLOOR PROTECTION
E
G
Figure 7b
8 ½" to 14" (figure 7a)
0" (figure 6) or 16" (figure 5)
COMBUSTIBLE
SIDE MANTLE
C
F
B
10"
8"
8 ½"
(figure 4)
10