Osburn SATURNA Installation And Operating Instructions Manual page 18

Natural gas & propane direct vent gas fireplace insert
Table of Contents

Advertisement

6.
For installations that do require the removal of the vent connector plate:
a.
Detach the vent connector plate by removing the screw securing the positioning strip to
the top of the air jacket (Figure 11) and slide the vent connector plate off to the rear
(Figure 12).
b.
Liberally apply High-temperature Sealant to the outsides of the vent collars.
c.
Attach the vent connector plate to the appropriate vent liners and secure with three
screws each and/or hose clamps. The vent connector plate should be located 16"-20"
(406-508mm) above the hearth.
d.
Push the insert back into the enclosure, feeding the positioning strap through the slot at
the top rear of the air jacket. Ensure that the strap passes freely under the air jacket
and that it doesn't get caught in parts protruding from the firebox top. Continue to push
the insert back as the strap is fed through until the hole on the strap lines up with the
corresponding hole on the air jacket. A screwdriver can be used, if required, to help pull
the strap forward. Secure the strap in position by replacing and tightening the screw in
the top of the air jacket (Figure 11).
e.
Bend the forward end of the strap back and up against the fireplace front so that the
faceplate can be installed (Figure 11).
Figure 12
18