Access module
Hide thumbs Also See for SmartAX MA5603T:
Table of Contents

Advertisement

SmartAX MA5600T/MA5603T/MA5608T Multi-service
Access Module
Commissioning and Configuration Guide
2.
Step 12 Apply ONT voice service profiles
After ONT voice service profiles are applied, if parameters in those profiles are changed, those
profiles must be reapplied so that the changed parameters can take effect.
1.
2.
Step 13 (Optional) Configure the H.248 user codec.
Issue 01 (2014-04-30)
If parameters of an MGC interface profile are changed, the MGC interface profile must be
reapplied to the ONT so that the changed parameters can take effect.
huawei(config-if-gpon-0/1)#if-h248 add 0 1 1 mgc-profile profile-id 2
huawei(config-if-gpon-0/1)#if-h248 add 0 2 1 mgc-profile profile-id 2
Add PSTN users.
For ONT 1 and ONT 2, create a PSTN user, set the MG ID to 1 (identical to the MG ID of
the H.248 interface), and set the physical terminal port ID to A0 and A1.
huawei(config-if-gpon-0/1)#mgpstnuser add 0 1 1 mgid 1 terminalid A0
huawei(config-if-gpon-0/1)#mgpstnuser add 0 2 1 mgid 1 terminalid A1
Run the display mgpstnuser attribute command to check whether the configuration of
the PSTN user is properly set.
huawei(config-if-gpon-0/1)#display mgpstnuser attribute 0 1 1
------------------------------------------------------------------------------
F/S/P
ONT ID
Port ID
MG ID
Terminal ID
...//The rest of the response information is omitted.
huawei(config-if-gpon-0/1)#display mgpstnuser attribute 0 2 1
------------------------------------------------------------------------------
F/S/P
ONT ID
Port ID
MG ID
Terminal ID
...//The rest of the response information is omitted.
Apply an interface common profile.
Run the if-h248 attribute command to apply an interface common profile to an H.248
interface or configure the interface customized parameters, or run the ont-if-h248 bat-
apply command to bulk apply the interface common profiles to H.248 interfaces. If you
use these two commands to apply the interface common profiles or configure the interface
customized parameters repeatedly, the last configurations take effect.
In this example, the default interface common profile, namely interface common profile 1
is used.
Apply a POTS port profile.
Run the pstnport electric command to apply a POTS port profile to an H.248 interface or
configure the interface customized parameters, or run the ont-pstnport electric bat-
apply command to bulk apply the POTS port profiles to H.248 interfaces. If you use these
two commands to apply the POTS port profiles or configure the interface customized
parameters repeatedly, the last configurations take effect.
In this example, the default POTS port profile, namely POTS port profile 1 is used.
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
: 0/1/0
: 1
: 1
: 1
: A0
: 0/1/0
: 2
: 1
: 1
: A1
19 IPv6 Configuration
1931