5.12.6.3 Setting the Timer Duration Time

You can set the Timer 1 duration by setting the TimerDuration parameter. The units for setting this
parameter are µs and the value can be set in increments of 1 µs.
To set the duration for Timer 1:
1. Use the Timer Selector to select Timer 1.
2. Set the value of the TimerDuration parameter.
You can set the TimerSelector and the TimerDuration parameter value from within your application
software by using the Basler pylon API. The following code snippet illustrates using the API to set
the selector and the parameter value:
camera.TimerSelector.SetValue(TimerSelector_Timer1);
camera.TimerDuration.SetValue(10.0);
You can also use the Basler pylon Viewer application to easily set the parameters.
For more information about the pylon API and the pylon Viewer, see Section 3.1 on

5.13 Significance of I/O Line Status

5.13.1 Line Status for Input Lines

This section informs about the relation between input line status and certain external conditions.
The opto-isolated and the GPIO input lines are considered.
The line status information depends, among others, on whether the input line inverter is disabled or
enabled (Section 5.11.3 on
Make sure the ground for opto-isolated I/O and the ground of the power supply for the opto-isolated
input line are connected to the same ground.
For applicable pins, see
and
Figure
44.
Basler ace USB 3.0
page
94).
Table 20 on page
68, and for line schematics, see
Physical Interface
page
61.
Figure
40,
Figure
43,
103

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Aca2440-35Aca2040-120Aca2440-75

Table of Contents