Electrical Specifications - Daikin ALTHERMA HT ERSQ 011 AA Service Manual

Table of Contents

Advertisement

ESIE09-08A
Outdoor units
Sound Level
Heating
Sound Power
(nominal)
Sound Pressure
Refrigerant
Type
Charge
Control
Nr of Circuits
Refrigerant Oil
Type
Charged Volume
Piping
Liquid
Quantity
Connections
Type
Diameter (OD)
Gas
Quantity
Type
Diameter (OD)
Drain
Quantity
Diameter (OD)
Piping Length
Minimum
Maximum
Equivalent
Chargeless
Additional Refrigerant Charge
Installation
Maximum
height
difference
Heat Insulation
Defrost Method
Defrost Control
Capacity Control Method
Safety Devices (pressure)
Safety Devices (fan)
Safety Devices (inverter)
Safety Devices (pcb)
Standard
Item
Accessories
Quantity
Design pressure (high pressure side)
Notes
(1): for details see operation range TW drawing

Electrical Specifications

Power Supply
Name
Phase
Frequency
Voltage
Voltage Range
Minimum
Maximum
(2)
Current
Z-max
(3)
Minimum Ssc
value
Maximum
Heating
running Current
Recommended fuses
Wiring
For power
Quantity
Connections
supply
Wire type
For connection
Quantity
with indoor unit
Remark
Power Supply Intake
Notes
(1): European/International Technical Standard setting the limits for harmonic currents produced by equipment connected to public low-voltage systems
with input current > 16A and  75A per phase
(2): In accordance with EN/IEC 61000-3-11
(6)
connected only to a supply with Zsys
(3): Short-circuit power
(4): Select diameter and type according to national and local regulations
(5): European/International Technical Standard setting the limits for voltage changes, voltage fluctuations and flicker in public low-voltage supply
systems for equipment with rated current  75A
(6): System impedance
Specifications
ER(S/R)Q011AA(V1/Y1)
dBA
dBA
kg
Expansion valve (electronic)
l
mm
mm
mm
m
m
m
m
kg/m
m
Sensor for outdoor heat exchanger
Fan motor thermal protector
Inverter overload protector
bar
ER(S/R)Q(011/014/016)AAV1
Hz
V
V
V
kVa
Equipment complying with EN/IEC
A
A
(5)
, it may be necessary to consult the distribution network operator to ensure that the equipment is
 Zmax
ER(S/R)Q014AA(V1/Y1)
R-410A
4,5
Expansion valve (electronic)
1
Daphne FVC68D
1,5
1
Flare
9,52
1
Flare
15,9
3
26 x 3
3
50
63
10
see installation manual
see installation manual
30
Both liquid and gas pipes
Both liquid and gas pipes
Reversed cycle
Sensor for outdoor heat exchanger
temperature
Inverter controlled
HPS
Fan motor thermal protector
Inverter overload protector
PC board fuse
Installation manual
1
40
ER(S/R)Q(011/014/016)AAY1
1~
50
220-240
198
254
0,28
(1)
61000-3-12
27
32
2G
(4)
Note
2
F1+F2
Both indoor and outdoor unit
ER(S/R)Q016AA(V1/Y1)
See technical data
R-410A
4,5
Expansion valve (electronic)
1
Daphne FVC68D
Daphne FVC68D
1,5
1
Flare
9,52
1
Flare
15,9
3
26 x 3
3
50
63
10
see installation manual
30
Both liquid and gas pipes
Reversed cycle
Reversed cycle
Sensor for outdoor heat exchanger
temperature
Inverter controlled
Inverter controlled
HPS
Fan motor thermal protector
Inverter overload protector
PC board fuse
Installation manual
Installation manual
1
40
3~
50
380-415
342
440
-
-
13,5
16
4G
(4)
Note
Specifications
R-410A
4,5
1
1,5
1
Flare
9,52
1
Flare
15,9
3
26 x 3
3
50
63
10
30
temperature
HPS
PC board fuse
1
40
7