Daikin ALTHERMA HT ERSQ 011 AA Service Manual page 87

Table of Contents

Advertisement

ESIE09-08A
Remote controller room temperature control
When the reheat temperature is reached, the further heat up till storage temperature of the domestic hot
water tank will be decided by the remote controller room thermostat in order to prevent that the room
temperature drops too much.
1. Reheat operation
Function
When requesting space heating and domestic water heating (reheat) at the same time. This involves
that the minimum reheat temperature is reached (setting [b-00]) during space heating operation. The
3-way valve will switch over to the domestic hot water side. The domestic water will be heated till
maximum reheat temperature (setting [b-01]). The 3-way valve will switch back to original position,
then space heating will start again.
During the reheat operation, the system does not take care about the room temperature. This means
that during simultaneous demand, the reheat operation has priority over the room temperature.
K
E
D
J
C
H
B
A
M
A
Operation
Space heating
Domestic water heating
B
Domestic hot water reheat thermo-on request
C
Domestic hot water tank temperature
D
Room temperature thermo-on request
E
Remote controller room temperature
F
Domestic hot water lower limit temperature
G
Domestic hot water upper limit temperature (maximum possible storage temperature) [b-03]
H
Domestic hot water reheat minimum temperature [b-00]
J
Domestic hot water reheat maximum temperature [b-01]
K
Remote controller thermostat set point
M
Simultaneous demand
N
ONLY space heating request
ON
ON
OFF
OFF
+0.5°C
–0.5°C
–3.0°C
ON
OFF
G
75°C
F
35°C
ON
OFF
N
Outline of Control (Indoor Unit)
75