12. T
ECHNICAL SPECIFICATIONS
12.1. General
Nominal capacity
• cooling
• heating
Dimensions H x W x D
Weight
• machine weight
• operation weight
Connections
• water inlet/outlet
• water drain
• refrigerant liquid side
• refrigerant gas side
Expansion vessel
• volume
• maximum working pressure (MWP)
Internal water volume
Pressure relief valve water circuit
Operation range - water side
• heating
• cooling
Operation range - air side
• heating
• cooling
• domestic hot water by heat pump
(a) MBSP = Male British Standard Pipe
12.2. Electrical specifications
Standard unit (power supply via outdoor unit)
• power supply
Backup heater
• power supply
• maximum running current
EKHBX016BB3V3S
Indoor unit for air to water heat pump system
4PW62598-1 – 10.2010
Heating/cooling models (EKHBX)
Refer to the Technical Data
Refer to the Technical Data
922 x 502 x 361
48 kg
61 kg
1-1/4" MBSP
hose nipple
Ø9.5 mm (3/8 inch)
Ø15.9 mm (5/8 inch)
10 l
3 bar
5.5 l
3 bar
+15~+55°C
+5~+22°C
–20~+35°C
+10~+46°C
–20~+35°C
Heating/cooling models (EKHBX)
230 V 50 Hz 1P
See
"Connection of the backup heater power supply" on page 19
See
"Connection of the backup heater power supply" on page 19
(a)
Installation manual