Advertisement

OmniCare EVC System
Installation & Commissioning Manual
4.6.3.2 Example 2 - Slave Control Panel operating Remote

4.6.4 Fault Relay Operation (JP2 PC1234)

62
Units 8 to 18 & 41 to 54
Slave Control Panels only require zone switches for the number
of remotes they will be operating. In the following example the
Top Switch Panel will be controlling Remote Units 8 to 18 and
the Lower Panel will be controlling Remote Units 41 to 54.
1. Using JP1, 2 and 3, set the Top Switch Panel to have a Base
Address of "1" and the Lower Switch Panel to a Base Address
of "33".
2. Set the Offset of the Top Switch Panel to "7" (Base Address of
1 + Offset of 7 = Zone 8).
This is the top right Red LED on the first row.
3. Set the Range of the Top Switch Panel to "11"(the number of
remotes the top panel will be controlling).
This is the third from left on the second row Yellow LED.
4. Set the Top Switch Panel to be Master (ensure the LEDs are
flashing faster than the lower panel).
5. Set the Offset of the Bottom Switch Panel to "8" (Base
Address of 33 + Offset of 8 = Zone 41).
This is the Bottom Left Red LED on the second row.
6. Set the Range of the Bottom Switch Panel to "14". This is the
third from right on the second row Yellow LED.
7. Ensure the Bottom Switch Panel is not set to be the Master
Panel (LEDs flashing slower than the Top panel).
Set the jumper to determine the required Fault Relay state.
The Fault Relay can be set for contact closure on fault (NO) or
contact opening on fault (NC).
C O M M U N I C A T I O N S