C O M M U N I C A T I O N S
4.6 C

4.6.1 Overview

4.6.2 Zone Address Settings (JP1, JP2, JP3 PC1233)

OmniCare issue 1
P
ONTROL
ANEL
The Master Control Panel must have one button for each Remote
Unit on the system, whereas Slave Panels only need buttons for
the Remote Units they will be able to communicate with.
Control Panels are fitted with up to 8 "Switch Panels". Each of
these switch panels has 16 buttons and controls upto 16 Remote
Units, making a potential maximum of 128 Remote Units per
Control Panel.
Each of the "Switch Panels" needs to be set up for the correct Base
Address of the Remote Units that it will operate. This is set using
jumpers on the board and is explained in Section 4.6.2.
Slave Control Panels only have buttons for Remote Units that
they will control, so the Switch Panels have to be configured for
those remotes. In addition to setting the Base Address, each
switch panel can be set to have an "Offset" (how many above the
Base Address to start) and a "Range" (how many buttons to use).
Refer to Section 4.6.3 for more details.
Figure 4.5 — Expanded View of Jumper Locations
S
ETTINGS
OmniCare EVC System
Installation & Commissioning Manual
59