Power Management - Cisco Catalyst 6500 Series Hardware Installation Manual

Hide thumbs Also See for Catalyst 6500 Series:
Table of Contents

Advertisement

Chapter 1
SIP, SSC, and SPA Product Overview

Power Management

If the power limit is exceeded, the SIP and SPA is not powered up and an error message is displayed.
Router#%C7KPWR-SP-4-POWERDENIED:insufficient power, module in slot 3 power denied.
On a Catalyst 6500 Series switch, use the show power command on the Route Processor to determine
how much power you have available in the chassis and how much is being used or reserved by line cards,
supervisor engines, and fan trays.
The following example shows the show power command on a Catalyst 6500 Series switch:
Router# show power
system power redundancy mode = combined
system power redundancy operationally = non-redundant
system power total = 1869.42 Watts (44.51 Amps @ 42V)
system power used = 1302.42 Watts (31.01 Amps @ 42V)
system power available = 567.00 Watts (13.50 Amps @ 42V)
Power-Capacity PS-Fan Output Oper
PS Type Watts A @42V Status Status State
---- ------------------ ------- ------ ------ ------ -----
1 PWR-1900-AC/6 1869.42 44.51 OK OK on
2 none
Pwr-Allocated Oper
Fan Type Watts A @42V State
---- ------------------ ------- ------ -----
1 FAN-MOD-6HS 180.18 4.29 OK
Pwr-Requested Pwr-Allocated Admin Oper
Slot Card-Type Watts A @42V Watts A @42V State State
---- ------------------ ------- ------ ------- ------ ----- -----
3 7600-SIP-400 265.02 6.31 265.02 6.31 on on
4 7600-SIP-200 200.34 4.77 200.34 4.77 on on
5 unknown 328.44 7.82 328.44 7.82 on on
Catalyst 6500 Series Switch SIP, SSC, and SPA Hardware Installation Guide
1-9
OL-9041-04