Check for Console power
The console is powered by a rechargeable 6-volt battery. Check the
battery by pressing the START key. The console should light up, and
the MESSAGE CENTER should display a prompt to set up a workout.
If this does not occur, mount the Life Fitness Cross-Trainer and begin
pedaling. The console should then light up, making it possible to
program a workout. Pedal for 10 to 20 minutes at 1.5 mph (2.4 kph)
or faster during a workout to charge the battery. Afterwards, the ped-
al action during workouts keeps the battery charged. If the console
still does not light, contact Life Fitness Customer Support Services
(see page one of this manual for more information).
Note: Optional external power supply can be used for CLSX units. Use only the power supply provided by Life Fitness in
order to insure against unsafe operation.
Grounding Instructions (Applicable for Units Using External Power Supply)
This Life Fitness product must be properly grounded. If the unit malfunctions or breaks down, proper grounding pro-
vides a path of least resistance for the electric current, which reduces the risk of shock to anyone touching or using the
equipment. Each unit is equipped with an electrical cord, which includes an equipment grounding conductor and a
grounding plug. The plug must be inserted into an outlet that has been properly installed and grounded in accordance
with all local codes and ordinances.
A temporary adapter MUST NOT BE USED to connect this plug to a two-pole receptacle in North Amer-
ica. If a properly grounded, 15amp outlet is not available, one must be installed by a qualified electri-
cian.
IL EST ABSOLUMENT INTERDIT d'employer un adaptateur temporaire pour brancher cette fiche sur une
prise bipolaire en Amérique du Nord. Si aucune prise de 15 A correctement mise à la terre n'est dis-
ponible, en faire installer une par un électricien qualifié.
DANGER: A risk of electrical shock may result from improper connection of the equipment-grounding
conductor. Check with a qualified electrician if in doubt as to proper grounding technique. DO NOT
modify the plug provided with the product. If it will not fit an electrical outlet, have a proper outlet in-
stalled by a qualified electrician. Any modification to the electrical plug will result in a voided warranty.
Un branchement incorrect du conducteur de mise à la terre peut entraîner des risques de décharge
électrique. Consulter un électricien si des doutes subsistent quant à la technique de mise à la terre. NE
PAS MODIFIER la fiche fournie avec l'appareil. Si elle ne s'adapte pas à une prise, faire installer une prise
correcte par un électricien qualifié. Toutemodification à la fiche annule la garantie.