Download Print this page

Installed Rogue2 Structural & Installation Checklist; Daily/Weekly Maintenance Of The Rogue2; Applicable Standards And Codes; Assembly And Installation - S.R.Smith rogue2 Owner's Manual

Pool slide

Advertisement

INSTALLED ROGUE2 STRUCTURAL & INSTALLATION CHECKLIST
After installation and prior to the first use of the ROGUE2 and periodically (see
DAILY/WEEKLY MAINTENANCE OF THE ROGUE2) thereafter the owner must:
1. Inspect the runway for visible cracks or tears.
2. Inspect the ladder for sharp edges, protrusions, cracks or tears.
3. Inspect ladder and pedestal mounting areas for loose or corroded fasteners.
4. Measure the following dimensions and compare with the Manufacturer's
Placement Instructions on pages 5, 6, and 7.
 Measure the depth of water in front of the slide exit. (4-6") min. depth at a
distance of (4-6") from exit end of slide.
 Measure the height of the slide runway exit above the water. (20" max.)
 Measure the distance between the slide centerline and the edge of other
pool equipment.
5. Observe the position of the exit of the slide as shown in Figures 2, 3 and 5 on
pages 6 and 7.
6. Read, understand and enforce all safety and use instructions on the slide.

DAILY/WEEKLY MAINTENANCE OF THE ROGUE2

1. When hosing down the deck, hose your Rogue2 to wash away any dust, dirt or
other debris, which may have accumulated.
2. Be sure that all connections are secure. Tighten hardware if necessary.
3. All polyethylene parts require little maintenance. Hose and wipe to clean.
While cleaning slide, check and see that all nuts and bolts are tight and secure.
4. Inspect the runway for visible cracks or tears, sharp edges and protrusions.
5. Inspect all attachment points for loose or corroded fasteners.
6. Inspect all ladder tread or step-attachment points for evidence of shear, bending
yield, or fatigue in the ladder steps, rails, or attachments means. Yield is
evidenced by crystallization or fine cracking of the ladder tread and/or surface.
7. Inspect the ladder handrails for rigidity and attachment.

APPLICABLE STANDARDS AND CODES

The installation of the Rogue2 must comply with all applicable governmental and
building codes.
All S.R. Smith Rogue2 slides are inspected prior to shipment from the factory. Proper
assembly and installation is mandatory. Improper assembly and installation voids S.R.
Smith's warranty and may affect the safety of the user. It is the installer's responsibility
to ensure that the structural integrity of the concrete pad prior to installation of the slide.

ASSEMBLY AND INSTALLATION

5

Advertisement

loading