Installation and Connection
3.2.3.1 Input Connections
The minimum recommended connection at the servo drive is shown in
a circuit breaker can be used in place of the contactor and ON/OFF switch.
The point to connect the PE can be observed in
3
DANGER!
Provide a disconnect device for the input power supply of the servo drive.
This device shall disconnect the input power supply for the servo drive when needed (for instance,
during servicing).
DANGER!
Montez un dispositif de coupure sur l'alimentation du Entraînement d'asservissement.
Ce composant déconnecte l'alimentation du Entraînement d'asservissement si cela est nécessaire
(ex. pendant l'entretien et la maintenance).
ATTENTION!
The power supply that feeds the servo drive must have a grounded neutral.
NOTE!
The power supply voltage must be compatible with the servo drive rated voltage.
3-12 | SCA06
Figure 3.4 on page
3-8.
Figure 3.6: Input connection
Figure 3.6 on page
3-12. As an alternative,
1 – ON/OFF switch
2 – Power supply
3 – Contactor
4 – Fuses