Reservation Mode For Manual Transmissions - Firstech CM5200 Installation Manual

Table of Contents

Advertisement

(manual transmission) mode, the system must be set up in Reservation mode prior to the vehicle being
able to remote start. IMPORTANT: All warranties or claims are void if a controller with a cut loop is
installed on a vehicle with a manual transmission.

Reservation Mode for Manual Transmissions

To remote start a manual transmission vehicle, the system must first be set up in reservation mode.
Reservation mode is designed to prevent the vehicle from remote starting while the transmission is in
gear.
Installation Requirements
1. The vehicle's door triggers must be connected to the control module. Prior to making final connections,
test the factory door triggers to ensure that they are functioning properly.
2. The vehicle's emergency/parking brake wire must be connected to the control module. The proper
vehicle wire usually provides a negative (-) trigger while the emergency / parking brake is set.
3. The vehicle's clutch must be momentarily bypassed while the remote start cranks the engine. This
momentary bypass simulates the clutch being depressed. For complete details on how to wire a
momentary clutch bypass consult your CompuTech program or contact our technical support department
by calling 888-820-3690.
IMPORTANT: Do not install a remote start in manual transmission vehicles with convertible / removable
tops and in user's vehicles that leave their windows down. Firstech nor their authorized dealers will
assume responsibility for improper use or install.
Activating Reservation Mode
STEP 1: Start the vehicle with the key. Place the transmission in neutral, remove pressure from the
pedal brake, and set the emergency/parking brake.
STEP 2: Remove the key from the vehicle's ignition. The vehicles engine should remain running even
after the key has been removed. If the vehicle does not remain running, check the emergency / parking
brake connection.
STEP 3: Exit the vehicle and close the door. The vehicle's engine should shut off upon closing the door.
If the vehicle's engine does not shut off, check the door trigger connection or wait for the factory dome-
light to go out. The Firstech system is in reservation mode and the vehicle is ready to safely remote start.
Additional Notes
Reservation mode will be cancelled if the control module recognizes the vehicles door, hood or trunk
opening – or if the alarm is triggered. Each time the end user wants to remote start their manual
transmission vehicle, they must set the control module in reservation mode. Reservation mode settings
can be programmed with Option 1-06.
9
4-03
Aux 1 Output Control
– This option changes the behavior of the default auxiliary wire on
Connector 3. This is a small white wire that is marked Horn output. The SF version makes this
wire an auxiliary output. With this option you can change the output to Horn or Status output.
4-04
Aux 2 Output Control
– This option changes the behavior of the default auxiliary wire on
Connector 3. This is a small violet wire that is marked Dome Light output. The SF version makes
this wire an auxiliary output. With this option you can change the output to Dome Light or Defrost
output.
4-05
Secure Aux Output
– On the default setting, button 4 on the remote must be pressed first before
Aux 1 or Aux 2 can be triggered. This prevents accidental triggering of the outputs. Option setting
II turns this feature off.
4-06
Auxiliary Input 1
– This option changes the input of the grey/white wire on the green plug.
Please see the option table for settings.
4-07
Auxiliary Input 2
– This option changes the input of the black/white wire on the green plug.
Please see the option table for settings.
4-09
Glow Plug or Key Sense
– Default setting sets the wire as a glow plug input. Option setting 2
changes the wire to a key sense input. Key sense can be used to prevent reservation mode from
setting and the system from passive arming while the key is still in the ignition. Key sense also
turns off dome-light supervision when the key is inserted into the ignition.
4-11
Bypass Brand Through RS232 Port
– Default setting allows for compatibility with ADS Idatalink
modules. Setting 2 changes compatibility to Fortin bypass modules. This is only available on the
CM5000 and CM5200.
nd
4-12
2
Ignition Option – This option changes the behavior of previous POC3 or the green wire on
nd
Connector 3. From negative 2
ignition output you can change to negative 2
or a ground when armed (GWA).
nd
4-13
2
Accessory Option – This option changes the behavior of previous POC4 or the white/black
nd
wire on Connector 3. From negative 2
accessory output you can change to negative 2
accessory, starter or a horn honk output.
nd
4-14
2
Starter Option – This option changes the behavior of previous POC2 or the red/black
nd
wire on Connector 3. From negative 2
starter output you can change to negative 2
ignition, accessory, or a dome light output.
Option Programming
Option Programming Using the OP500
The OP500 can be used to program any available option.
STEP 1: Using the blue connector on the top of the OP500, connect it to the control module via the
antenna wire. (Use the included extension cable if necessary.) Once connected, the OP500 will power up
as long as the main ignition harness to the controller has been connected properly.
nd
accessory, starter
nd
nd
22

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cm5000

Table of Contents