Option Programming Tables
OPTION GROUP 1
Feature
Default Setting - I
Optional Setting - II
1-01
Unlock before, Lock after, starting
Off
1-02
Lock / Unlock pulse duration
0.8 sec
2.5 sec
1-03
Driver's priority unlock
Off
1-04
Double pulse unlock
Off
After Start Shutdown
1-05
Rearm Output
After Shutdown Only
and First Lock
Passive locking with
No Passive Locking with
1-08
Locking while in Passive Arming
Passive Arming
Passive Arming
1-09
Ignition controlled door locks
Off
Ignition and Acc Pulse -
1-11
Ignition / Accessory Out Upon Unlock
Off
same timing as disarm
pulse
1-13
Double Pulse Disarm Input
Single Pulse
Double Pulse
Auto Lock Mode (2 Way International
1-14
Off
Remotes)
OPTION GROUP 2
Feature
Default Setting - I
Optional Setting - II
2-01
Tach Sensing Method
Optimal Tach Method
Previous Tach Method
2-02
Turbo Timer
Off
2 Min
2-03
Diesel Timer
Wire
3~99sec (10sec Default)
2-04
Trigger Start
Off
Single Pulse
3 Hour (4 minute
1.5 Hour(4 minute
Timer Start, or, Minimum Interval
2-06
runtime, double for
runtime, double for
Between Cold Starts
Diesel)
Diesel)
2-07
Remote Start Runtime
15 Min
25 Min
2-10
Engine Sensing
Tach
Alternator
+0.2 Seconds to Crank
2-12
Crank Time
Standard
Time
OPTION GROUP 3
Feature
Default Setting - I
Optional Setting - II
3-03
Dome Light Delay
Off
3-04
Starter-Kill Relay
Anti-Grind + Starter Kill
Anti-Grind
3-06
Factory Alarm Option (CM5200 Only)
Off
3-07
Siren Duration (Upon Alarm Trigger)
30 Sec.
60 Sec.
3-08
Horn Output (CM5200 Only)
On Double Lock Only
On Lock and Unlock
Constant Output
3-09
Horn Output When Alarm is Triggered
Pulsed Output
(Secondary Siren)
19
Optional Setting - III
Optional Setting - IV
Lock After Remote Start
Lock After Shutdown
On
Only
Only
0.125 sec
3.5 sec
On
On
On
On
Optional Setting - III
Optional Setting - IV
Low Threshold Tach
Method
5 Sec. Delay
15 Sec. Delay
Double Pulse
Triple Pulse
45 Min
3 Min
No Connection –
No Connection – 1.5
Voltage Sensing
Second Crank Not for
Not for Manual
Manual Transmissions
Transmissions
V.1 or greater
+0.6 Seconds to Crank
(-)0.2 Second Crank
Time
Time
(Voltage Sensing Only)
Optional Setting - III
Optional Setting - IV
Auto
Anti-Grind +
Passive Starter Kill
On
On Lock, Unlock, and
On Double Lock and
Start
Start
CM5000 Wiring Schematic (Alarm and Remote Start)
The CM5000 is the control module for all alarm and remote start combo units. This controller is universal
regardless of remote or antenna type.
CN9
( - ) Switch
3 Gray
1 Red
Plug In
LED/Valet
( + ) Led
2 Gray
3 Red / White
Switch
CN1
(N/A on
( - ) Ground
1 Gray / Black
5 Violet
V.SF)
7 Green and
Red
2 Black /
LED ( + )
CN5
White
LED
LED ( - )
1 Black
CN2
LED
4 Yellow
ADS Blade Connector
(20 Pin Harness)
CN7
( + )
3 Red
RPS
Knock
2 White
Sensor
1 Green /
( - )
1 Black
White
3 Red / Black
5 Green
( - )
4 Black
7 White / Black
CN3
( + )
3 Red
9 Black
CN8
Antenna
TX
2 White
11 Orange
13 Orange /
RX
1 Yellow
White
15 White
17 Violet
1st Stage Shock
4 Yellow
( + )
3 Red
CN6
2nd Stage
Shock
2 White
Shock
Sensor
( - )
1 Black
CN4
1st Stage
4 Grey / White
CN10
( + )
3 Red
Optional
2 Black /
Sensor
2nd Stage
White
Input
( - )
1 Black
CN12
RS232
2 Black
CN11
1 Black /
Thermistor
White
Blade Cartridge Slot - Please
Green/White Loop
visit
Cut=Auto Trans. Uncut=Manual
www.idatalink.com/compustar
Trans.
for compatibility and more
information. This slot is empty
and has a plastic cover that slides
( + )
off.
IMPORTANT: Manufacturer or
seller will have no responsibility for
any injuries and/or damages
caused by improper care of the
( + )
product such as decomposition,
Jumpers
conversion, and transform done by
a user voluntarily
Default
( + ) Parking
Lights
Default
2 Green / White
1: ( + ) 12v Constant
2: ( + ) Parking Light
3: ( + ) 12v Constant (Separate
4 White
4: ( + ) Accessory
nd
Red/White prewired to 2
Relay)
5: ( - ) When Armed prewired to
6: ( + ) Starter (prewired to Starter
6 Yellow
Starter Kill Relay
Kill Relay)
7: ( + ) Ignition and (Separate Red
8 Black
8: ( - ) Ground
prewired to Starter Kill Relay)
1 Red
1: ( + ) 12v Back Up Battery
2 Black
2: ( - ) Ground Back Up Battery
Please see the installation manual
This harness is not included with
for the Blade module for details.
the CM5000.
2 Lt Blue
1: ( - ) Parking Lt. Output
2: ( - ) E-Brake Input
4 Lt. Blue /
3: ( - ) Starter Output
4: ( + ) Brake Input
White
6 Violet / Black
5: ( - ) Ignition Output
6: ( - ) Trunk Input
8 Red / White
7: ( - ) Accessory Output
8: ( - / + ) Door Input
10 Brown /
9: ( - ) Status Out (GWR)
10: ( - ) Glow Input/Key Sensing
White
12 Pink
11: ( - ) Rearm Output
12: ( - ) Slave/Closed Loop Input
14 Yellow /
13: ( - ) Disarm Output
14: (AC) Tach / Alternator Input
Black
16 Gray / Black
15: ( - ) Aux 1 Output
16: ( - ) Hood Input
18 Brown
17: ( - ) Aux 2 Output
18: ( + ) Siren Output
None
Future use
2 Violet / White
( - ) Trunk release output
3 Orange /
( - ) Second Unlock Output
Black
4 Blue
( - ) Unlock Output
5 Blue / Black
( - ) Lock Output
None
( + ) 12v Constant Power
1 ( + )
2 ( - )
3 Data
4 Data
Every control module has this wire
intact and must be cut for automatic
( - )
Door Trigger Polarity
Default
( - )
Key Sense/Glow Plug Polarity
Trunk Release
Behavior of CN1, Pin 2
12
Need help?
Do you have a question about the CM5200 and is the answer not in the manual?
Questions and answers