13.6 Construction

Rated conditions for absolute pressure (from the differential pressure series), differential pressure and flow rate
In conjunction with dust
explosion protection
Rated conditions for level
Installation conditions
Installation instruction
Ambient conditions
Ambient temperature
Note
Measuring cell with silicone oil
filling
Display
Storage temperature
Climate class
Condensation
Degree of protection in
accordance with EN 60529
Degree of protection in
accordance with NEMA 250
Electromagnetic compatibility
Interference emission and
interference immunity
Process medium conditions
Process temperature
Measuring cell with silicone oil
filling
13.6
Construction
Construction for gauge pressure and absolute pressure (from the gauge pressure series)
Weight
Material
Wetted parts materials
Process connection
Oval flange
210
-20 ... +60°C (-4 ... +140°F)
specified through the flange
Observe the allocation of the max. permissible operating temperature to the max.
permissible operating pressure of the relevant flange connection.
-40 ... +85 °C (-40 ... +185 °F)
-30 ... +85 °C (-22 ... +185 °F)
-50 ... +85 °C (-58 ... +185 °F)
Permitted
IP65
NEMA 4X
In accordance with EN 61326 and NAMUR NE 21
Plus side: see the mounting flange
Minus side: -40 ... +100 °C (-40 ... +212 °F)
Approx. 1.5 kg (3.3 lb) for aluminum enclosure
Stainless steel, mat. no. 1.4404/316L or Hastelloy C4, mat. no. 2.4610
Stainless steel, mat. no. 1.4404/316L
SITRANS P DS III with PROFIBUS PA