9.3

Interface

HART (6 m, 12 m version)
Configuration
Display (local)
9.4

Outputs

Analog output
9.5

Construction

Process connections
Transducer/nosecone
Enclosure
Clear lid
Blind lid
Weight
Installation torques
SITRANS Probe LU240 with mA/HART
Compact Operating Instructions, 09/2021, A5E42673704-AE
Standard, integral to analog output
Local buttons, or engineering system (6 m, 12 m version),
such as Siemens SIMATIC PDM (via PC)
Multi-segment alphanumeric liquid crystal, with bar graph
(representing Level)
4 to 20 mA
800 ohms maximum
±0.0096 mA
Resolution of <1 μA
2" NPT (ASME B1.20.1) (tapered thread)
R 2" [(BSPT), EN 10226-1] (tapered thread)
G 2" [(BSPP), EN ISO 228-1] (parallel thread)
Buna-N seal
PVDF (polyvinylidene fluoride)
ETFE (ethylene-tetrafluoroethylene)
Body material
Electrical connections/cable
entries
Ingress protection
Plastic (PBT/PC - polybutylene terephthalate/polycarbonate)
Plastic (PC - polycarbonate)
0.93 kg
Cable gland to enclosure
(Siemens supplied, metric)
Technical specifications
Plastic (PBT/PC - polybutylene tereph-
thalate/polycarbonate)
2 x M20 x 1.5 (one general purpose
cable gland and one blocking plug
provided)
1 x 1/2" NPT
IP66, TYPE 4X
IP68, TYPE 6
10 Nm
9.3 Interface