1.22.6
Adjustment of the separation area
When the separation plate is attached using the thickness gage, there should be a 0.6±0.2mm clearance
between the separation mylar and the rubber of the feed roller (the difference by the side of the front and
rear is 0.2mm or less).
Adjust the gap between the separation mylar and the feed roller in the thrust direction by sliding the
bracket to right and left so that the gap becomes 0.3mm or more (see the view from B).
Bracket
Screw
Screw
Screw
A
Separation plate
Feed roller
0.3 or more
0.3 or more
Separation mylar
View from "A"
View from "B"(detailed drawing)
ADJUSTMENT
1 - 84