1.22.7
EEPROM Initialization, Sensor Adjustment and Test Mode
(1) EEPROM initialization and sensor adjustment
Whenever the logic PC board, aligning sensor, timing sensor or exit sensor is replaced, it is neces-
sary to initialize the EEPROM and adjust the sensor by adjustment mode (05).
If the initialization and/or adjustment is not performed, errors (paper jam etc.) may occur.
(2) Test mode
The independent test modes below can be performed by test mode (output check: 03). Refer to the
Service Manual for the PPC.
• Pick-up roller rotation
• Aligning roller rotation
• Transport belt rotation CW
• Transport belt rotation CCW
• Reversal roller rotation