27
Cleaning the camera
27.3 Infrared detector
27.3.1 General
Even small amounts of dust on the infrared detector can result in major blemishes in the
image. To remove any dust from the detector, follow the procedure below.
Note
•
This section only applies to cameras where removing the lens exposes the infrared detector.
•
In some cases the dust cannot be removed by following this procedure: the infrared detector must
be cleaned mechanically. This mechanical cleaning must be carried out by an authorized service
partner.
CAUTION
In Step 2 below, do not use pressurized air from pneumatic air circuits in a workshop, etc., as this air
usually contains oil mist to lubricate pneumatic tools.
27.3.2 Procedure
Follow this procedure:
1. Remove the lens from the camera.
2. Use pressurized air from a compressed air canister to blow off the dust.
#T559598; r. AB/ 9443/9443; en-US
75