Display
Explanation
If "F3" is displayed, there are problems with the condensation sensor. This
sensor only protects against overheating, and it has no influence on the
F3*
temperature regulation in the cabinet. It ought however to be replaced as
quickly as possible, so the protection against overheating is re-established
Faults in the second condensation sensor in connection with units with two
F4*'**
cooling motors (see fault message "F3").
Fault in the temperature sensor for PCL (hard chill). The sensor must be
F5
replaced, contact the service department. Affects only hard chill
Overheating of condenser or undercooling, filter mats or condenser fins
plugged up, fan defective, ambient temperature too high or low (unit not in
F7*
operation with ambient temperature of under +10 °C)
*does not apply for models with external cooling motors
** does not apply for the SF 550 / KP 60

Deleting alarm messages

 
A1
The A1 alarm is deleted by pressing the button
!Door must be closed first
The A2 alarm is deleted by pressing the button
A2
!The temperature in the cabinet must first be under the desired
maximum temperature (25°C Default)
 
 