Thawing Program; Manual Defrosting Of The Evaporator; Automatic Defrosting Of The Evaporator - Gram BAKER SF 550 User Manual

Hide thumbs Also See for BAKER SF 550:
Table of Contents

Advertisement

Thawing program

 
In connection with thawing, a defrosting heating element is used,
which is governed by the temperature that the room sensor measures.
The thawing program is only able to start when the desired
temperature value is set to between +2C and +8C.
The program is started by pressing the button
starts the function.
When the desired value is attained, an
acoustic signal will be emitted.
After the signal, defrosting is
commenced (if such is required based
upon the evaporator sensor's
temperature). Afterwards, the storage
program is switched to.
SF 550: -18ºC
KP 60/82: +4ºC
 

Manual defrosting of the evaporator

 
Manual defrosting is only possible as initial defrosting:
Start a program: Press on 
(wait for 10 seconds). 
Press on 
  in order to end/interrupt the program again. This then 
causes defrosting to be commenced  
Do not use pointed or sharp objects to make defrosting go faster!

Automatic defrosting of the evaporator

The unit performs automatic defrosting 1 to 8 times daily, when the "PCL",
"HCL" and "SCL" programs have finished. Defrosting cannot be concluded
manually! In connection with this, the internal temperature inside the unit is
shown before the defrosting process commences.
765041976
 
Rev. 000
.
19

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Process kp 60Process kp 82

Table of Contents