Temperature-controlled cooling (Soft Chill)

 
This program gently cools down to the selected, desired value
(controlled using room sensor).
Both compressors perform the cooling in parallel. The second compressor starts 15
seconds after the first one. The fan runs at a high RPM figure.
The program is started by pressing the button
Temperature changes with Soft Chill: The program is governed solely by the room
sensor. The air temperature and goods being chilled are thus taken into account. The
elapsed time has no effect on the course of the program. The cooling system works with
start/stop cycles with a gradient up to the preset storage temperature. The process stops
as soon as the temperature value reaches 0 °C, and the controls switch to the storage
program.
After pressing the
-
+ and
buttons will be blinking. The curve symbol for Soft
Chill will light up. The secondary display shows the program
name "SCL", and the tertiary display the selected, desired
temperature value. The + and
change the desired value, and
The primary display will now show the current temperature in the
room, the secondary display the program name "PCL" and the
tertiary display the selected, desired temperature value. The
curve symbol is now continuously displayed. In addition, the
connected elements will now be continuously lit: compressors,
fan symbol.
When the desired value is attained, an
acoustic signal will be emitted.
After the signal, defrosting is commenced
(if such is required based upon the
evaporator sensor's temperature). Then it
subsequently switches to the storage
program. Hence the desired value for the
storage program must always be set and
checked before starting "SCL"!
765041976
button, it will be lit continuously. The
-
buttons are used to
P
for starting the program.
Rev. 000
.
P
,
 
18