The user menu

The user menu is opened by pressing the
seconds.
Navigate through the menu using the using the
menu item is opened with the button
value. They are also used to navigate around in the submenu ("LAL"). The manner of
procedure is the same in the submenu. Altered values are saved by pressing on
acoustic signal!). The menu items or the menu are exited by pressing
Menu item
Description
DC
Dry cooling function *
LAL
Local alarm (display)
LHL
upper boundary value for
LAL
LHd
Delay for LHL
DA
Door alarm
Dad
Delay for door alarm
BU
Acoustic alarm for LAL
CAL
Temperature offset (sensor
harmonisation)
CA
Temperature offset sensor
input A (room sensor)
Temperature offset sensor
CE
input A (room sensor)
Relative (escorted) or
ALL
absolute (fixed) alarm limits
Number of defrosting cycles for
DEF
each 24 hours
765041976
-
+
and
-
+
P
. The
and
buttons increase or decrease the
Settings range
Activation: "ON"
Deactivation: "OFF"
+25 ... -35 °C
1 ... 120 min / in steps of 5 minutes
0 = off / 1 = on
0 ... 15 min
0 = off / 1 = on
-5 ... +5 K / steps of 0.5 K
-5 ... +5 K / steps of 0.5 K
ESC = escorted / FAS = fixed
0 ... 8
Rev. 000
button for approx. 3
buttons, after which the selected
.
Factory
setting
OFF
+25 °C
60 min
1
1
1
0.0 K
0.0 K
FAS
4
P
(receipt
20