Temperature alarm

The controller is equipped with a temperature alarm, which constantly monitors the cabinet
temperature. The
The following alarms can be displayed:
AL
low temperature alarm
AH
high temperature alarm
Id
open door alarm
Displaying alarm values:
Push the
displayed. Now, push
button to select the wanted value. Push
displayed.
Example – alarm AH:
9.0
the temperature alarm value is 8.0° C
dur
alarm duration
h01
the alarm lasted for 1 hour ....(continues)
n15
.... and 15 minutes
AH
selected alarm value
Each value is diplayed alternately for approx. 1 second.
To exit the alarm menu, push
"AH"). Push
Deleting alarms:
Push
, and keep pushed for 1 second. Push
push
. Then push
the display fashes "- - - -" for 4 seconds. The alarms are now deleted, the
turned off, and the controller returns to temperature display.
Gram-webshop.nl
lamp lights, if an alarm has occurred.
button, and keep pushed for 1 second. Push
and one of the alarm codes above is displayed. Use the
and the selected alarm is displayed (in this example
again, and the current cabinet temperature is displayed.
or
within 15 seconds and set "149". Push
or
until "LS" is
again, and the alarm values are
or
until "rLS" is displayed. Now
or
again, and
-LED is