10 - ELECTRICAL SYSTEM

10.1 - GENERAL INDICATIONS

CHECKING CONNECTORS

Check for corrosion, damp etc. in the connectors.
1. Disconnect:
- Connectors.
2. Dry:
- Each of the terminals with compressed air.
3. Connect and disconnect:
- The connector two or three times.
4. Check:
- Pull the conductor to check if it is loose.
5. Check:
- If the terminal comes loose, bend the pin (1) and refit
the terminal in the connector.
6. Connect:
- The connector.
N.B.
7. Check:
- The continuity of the circuit with a Multimeter.
N.B.
221
THE TWO PARTS OF THE CON-
NECTOR
MAKE
A
SOUND
WHEN THEY FIT TOGETHER.
IF THERE IS NO CIRCUIT,
CLEAN THE TERMINALS.
FOLLOW THE STEPS FROM (1)
TO (7) ABOVE ON INSPECTING
THE ELECTRICAL SYSTEM.
AS A PROVISIONAL SOLU-
TION, USE A CONTACT CLEA-
NER.