High Availability Configuration Guide

6.3.3 Set the Failover Condition

Step1
Click the Basic > SIP tab.
Step2
Verify that the Active-Standby mode is selected.
Step3
Select to enable or disable OPTIONS Keep-alive.
Step4
If disable is selected, skip to OPTIONS Keep-alive is disabled on page 123.
Step5
If enable is selected, then the following timers must be configured:
In the OPTIONS request period field, enter the interval between receiving the response (200) from the SIP
server to the previous OPTIONS and sending the next OPTIONS.
In the OPTIONS request timeout field, enter the period since the sending of the last OPTIONS with no
response by the SIP server.
Page to set failover condition
Figure 6-25
Step6
Click Save.
Step7
Skip to How to Manually Perform Switchover on page 125.