5.
Check the Terminator switches.
a.
For all display stations and printers except the personal
computer, 3179 Model 2, 3180 Model 2, 3196, and 4224.
1
If two cables are
connected, set the
Terminator switch
to 2.
1
-
T
If one cable is
connected, set the
Terminator switch
to 1.
b.
For the Personal Computer:
or
1
Display stations and
printers with only
one socket do not
have Terminator
switches.
Display Station Emulation Adapter
Enhanced Display Station Emulation Adapter
or
~------:
-----------
:--------
~--------------
.
-----------------
T
T
If two cables are
If one cable is connected, make
connected, make sure
sure switches 4 and 5 of the
switches 4 and 5 of
6-position switch assembly are
the 6-position switch
set to the On position; or, that a
assembly are set to
Terminator is attached and
the Off position.
switches 4 and 5 of the
6-position switch assembly are
set to the Off position.
-
T
The Enhanced Display Station
Emulation Adapter has
automatic termination built
in. Go to step 6 in this
section.
I I I I I.
~
Section 12.D Continued
----------------------------------------------------------------1
Responding to System Reference Codes and other Problems