Power Supplies; Non-Hot-Swap Power Supply Removal - IBM pseries 630 6C4 Installation Manual

Hide thumbs Also See for pseries 630 6C4:
Table of Contents

Advertisement

Power Supplies

DANGER
Do not attempt to open the covers of the power supply. Power supplies are
not serviceable and are to be replaced as a unit.
This system drawer has power supplies that have hot-swap capabilities. To use this
feature, you must have two power supplies in place.

Non-Hot-Swap Power Supply Removal

If you are servicing a system that has only one power supply installed, you must follow
the non-hot-swap power supply removal procedure. Systems that were configured with
one power supply at the factory have a power supply filler panel. The filler panel
protects the vacant power supply connector from dust or damage.
Before performing any of the following procedure, read and understand all of the safety
notices beginning with "Safety Notices" on page vii.
To remove a non-hot-swap power supply, do the following:
1. On a Model 6C4, open the front and rear rack doors and put the system into the
service position as described in "Placing the Model 6C4 into the Service Position"
on page 53.
On a Model 6E4, open the bezel door.
2. Shut down the system as described in "Stopping the System" on page 52.
3. Remove the service access cover as described in "Service Access Cover Removal
(Model 6C4)" on page 55 or "Service Access Cover Removal (Model 6E4)" on
page 57.
4. Remove the power supply cable from the rear of the power supply.
Eserver pSeries 630 Model 6C4 and Model 6E4 Installation Guide