Step 5. Read the Rack Safety Instructions

Before continuing, make sure you review the following instructions for mounting the
system drawer into the rack. If the system drawer was shipped already mounted in a
rack, go to Chapter 4, "Installing Options for the Model 6C4 and Model 6E4" on
page 49.

Rack Safety Instructions

v Do not install this unit in a rack where the ambient temperatures will exceed 40
degrees C.
v Do not install this unit in a rack where the airflow is compromised. Any side, front or
back of the unit used for air flow through the unit must not be in indirect contact with
the rack.
v Ensure that a hazardous condition is not created due to uneven mechanical loading
when installing this unit in a rack. If the rack has a stabilizer it must be firmly
attached before installing or removed this unit.
v Consider the connection of the equipment to the supply circuit so that the overloaded
circuits do not compromise the supply wiring or over-current protection.
v An electrical outlet that is not correctly wired could place hazardous voltage on the
metal parts of the system or the devices that attach to the system. It is the
responsibility of the customer to ensure that the outlet is correctly wired and
grounded to prevent an electrical shock.
When installing the Model 6C4, you will need the following items:
v Rack-Mounting Template
v 2 Slide Rail Assemblies
v Cable Management Arm
v Rack-Mounting Kit Envelope
v Screwdriver or similar tool if available
v
Eserver pSeries 630 Model 6C4 and Model 6E4 Installation Guide
12