Important! Status displays 306 (Power Low) and 307 (DC-Low) appear
naturally every morning and evening due to low solar irradiation. These
status messages are not the result of a fault.
(D)
(D)
(C)
(B)
(D)
2x
(C)
39
- „STATE_PS" ... Status display of
power stage sets
- Press „Enter" key (D)
- In this case for example the first
power stage set (PS00) is on
„Standby"
- „Standby" means no electricity is
being fed into the public mains
- Press „Enter" key (D)
- Display of the most recently
stored service code (e.g. „State
406")
Important! The most recently
stored service code and the display
„State Load" appear alternately.
- Press „Esc" key (C)
- The display for the first power
stage set (PS00) re-appears
- Change over to the second po-
wer stage set by pressing key (B)
- In this case for example the
second power stage set (PS01)
is on „Run"
- „Run" means intact delivery of
electricity to the public mains
- Press „Enter" key (D)
-
Display of the most recently
stored service code (e.g. „State---
-")
Important! The most recently
stored service code and the display
„State Load" appear alternately.
- Escape: Press „Esc" key (C)
twice